PORTARIA 453 PDF

adminComment(0)
    Contents:

Portaria - 01 de junho de Aprova o Regulamento Técnico que estabelece as diretrizes básicas de proteção radiológica em radiodiagnóstico médico e. Consulta Pública n° , de 28 de dezembro de DOU de 29/12/ A Diretoria Colegiada da Agência Nacional de Vigilância Sanitária, no uso das. A Portaria /98 do MS, que retrata a ICRP 60 (publicação nº 60, de ), define que a dose efetiva média anual não deve exceder a 20 miliSievert (mSv) em.


Portaria 453 Pdf

Author:ANNABELLE DETOMMASO
Language:English, French, Arabic
Country:Finland
Genre:Children & Youth
Pages:647
Published (Last):14.01.2016
ISBN:430-8-44333-579-2
ePub File Size:23.81 MB
PDF File Size:15.27 MB
Distribution:Free* [*Registration Required]
Downloads:24569
Uploaded by: DAMIEN

Vigilância Sanitária a aplicação de testes de qualidade de acordo com a Portaria /98 do Ministério da. Saúde. Foram utilizados simuladores específicos de. with a mean value 60% lower than the reference level established by the Order ( Portaria) Among the images evaluated, 98% fulfilled > 65% of the images. Portaria de 1 de junho de CVS SP nº 18 de junho de Ficha, portaria , norma cnen Ficha, Portaria ANVISA. Ficha, Portaria /.

Patologia ambiental: Rio de Janeiro: Guanabara Koogan; Soares JC.

Medeiros RB. Radiol Bras.

Azevedo ACP. Kaude J, Svahn G.

Absorbed, gonad and integral doses to the patient and personnel from angiographic procedures. Acta Radiol Diagn Stockh. Wholey MH.

Air isodose curves in a mammography room *

Clinical dosimetry during the angiographic examination: Exposure of the radiologist to scattered radiation during angiography.

Gustafsson M, Lunderquist A. Personnel exposure to radiation at some angiographic procedures.

The hazard of scattered radiation in a trauma intensive care unit. Crit Care Med. Occupational exposure in X Ray diagnosis in Brazil.

Diagnostic radiology is a field of physical medicine that uses X rays to obtain functional and anatomical information on the human body. The techniques associated to this area use X ray tubes as radiation sources, films to record information, and monitoring systems using television and computers for the digitalization of images.

Fluoroscopic equipment is considered as artificial springs of ionizing radiation and is used in diagnostic exams and procedures of vascular illnesses. The objective of this study was to critically analyze the protection methods regarding the radiation emitted by fluoroscopy used by professionals dealing with interventional radiology in a hospital environment.

ABC | Volume 112, Nº4, Abril 2019

An evaluation of protection methods adopted by professionals directly involved in procedures of interventional radiology was performed based on extensive literature review of textbooks and medical journals indexed on MEDLINE in Portuguese, English, French, and Spanish from to Radiation, ionizing, interventional radiology, fluoroscopy, radiation protection, X rays.

Patologia estrutural e funcional.

Patologia ambiental: Rio de Janeiro: Guanabara Koogan; Soares JC. Medeiros RB.

Services on Demand

Radiol Bras. Azevedo ACP. Kaude J, Svahn G. Absorbed, gonad and integral doses to the patient and personnel from angiographic procedures.

Acta Radiol Diagn Stockh. Wholey MH. Health effects of medical radiation on cardiologists who perform cardiac catheterization.

J Chin Med Assoc. Ionizing radiation-induced cataract in interventional cardiology staff. Rev Cardiovasc Med.

Occupational exposure to lowdoses of ionizing radiation and cataract development: a systematic literature review and perspectives on future studies.

Radiat Environ Biophys. Occupational radiation dose to eyes from interventional radiology procedures in light of the new eye lens dose limit from the International Commission on Radiological Protection.Cellular defense mechanisms against the biological effects of ionizing radiation.

Exposure of the radiologist to scattered radiation during angiography. The DoseCal input page is shown in Figure 1.

Personnel exposure to radiation at some angiographic procedures.

Radiation safety in the cardiac catheterization laboratory: operational radiation safety.